Brand Name : Neware
Model Number : CE-6002-60V100A
Certification : CE
Place of Origin : China
MOQ : 1 Unit
Price : USD negotiation per Unit
Payment Terms : T/T
Supply Ability : 50 Units Per Month
Delivery Time : 45 working days
Packaging Details : Wooden Box , W - D - H , 600 - 800 - 1800 mm
Voltage Range : 10V - 60V
Current Range : 0.5A - 100A
Precision : Positive and negative 0.02 percent of FS
Stability : Positive and negative 0.1 percent of FS
Current response time : less than 3ms 10 percent to 90 percent
Cycles times : 65535
Max steps : 254
Database : MySQL
Neware 60V100A Regenerative Battery Pack Tester of Electric Vehicle
CE - 6000 module pack testing system is a high - precision charging and discharging equipment specially developed for high - power battery pack testing . It has the characteristics of high dynamic response speed , high stability precision , multi - channel flexible configuration and so on . It supports pulse testing , cycle life testing and working condition simulation testing . The system has the function of multi - channel input and energy recovery , which can save a lot of electric energy consumed in the process of charging and discharging . Using bidirectional high - frequency DC converter topology and high - performance multi - channel 24 bit AD converter chip , the sampling resolution is higher than that of traditional single range equipment .
CE-6000 series battery testing system
Product introduction
1 . Power battery simulation test, rate test .
2 . Cycle life test .
3 . Power, capacity and energy detection .
4 . Virtual configuration of power battery pack: charge and discharge curve fitting, battery consistency detection and evaluation;
5 . High rate charge and discharge ability detection .
6 . Power battery, energy storage battery series module detection: monomer voltage, monomer temperature monitoring - high voltage equipment .
| Charge | Charge modes | Constant current , Constant voltage , Constant current and voltage , Constant power |
| Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity , - delta V | |
| Discharge | Discharge modes | Constant current , Constant voltage , Constant power , Constant resistance |
| Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity |
| Pulse | Charge | Constant current , Constant power |
| Discharge | Constant current , Constant power | |
| Min pulse width | 100ms | |
| Pulse counts | Each pulse step supports 32 different pulses | |
| Chg and Dschg switch | Supported | |
| Cut - off condition | Voltage , Time | |
| Simulated Condition | Charge modes | Constant current , Constant power |
| Discharge modes | Constant current , Constant power | |
| Cut - off condition | Time , Line Number | |
| Continuous switching Chg and Dischg | One simulation step can realize a continuous switching from charging to discharging | |
| Limit step number | 1 million | |
| Protection | Software protection | Power - off data protection |
| Off - line operation mode | ||
| User - defined protection conditions , such as upper and lower limited current / voltage , delay time , temperature , etc . | ||
| Charge and discharge efficifency | more than 90 percent | |
| Protection | Anti - surge , anti - islanding , over - under - frequency , over - under - voltage , phase - loss protection , etc. | |
| Protection grade | IP20 | |
| Channel parallel | supported , Parallel channels do not support pulse and simulation testing | |
| Energy feedback | The discharge energy can be fed back to the power grid | |
| Channels feature | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
| Channels control mode | Independent control |
| Noise | ≤65dB |
| Database | MySQL |
| Communication | TCP/IP |
| Operating system | Windows 7/8/10 64bit |
| Data export | EXCEL, TXT |
| Min. disk drive | 500GB |
| Communication port | Ethernet port |

|
|